CYY-QC2 Square carbon silicon sampling cups for C-Si analyzers. Integrated with Tellurium to measure C%, Si%, CE, and CEL. A flagship product in the Changyouyi square cup series.

0,6 – 1,6USD /piece

≈ 3,9 – 10,6CNY / piece· Special offer for CNY payments

Reference Conversion:0,6 – 1,6 USD

Reference rate, updated 10/2026. Final price based on official quote.

Minimum order:1 box(100 or 200 pieces/box)

Checkout & Delivery

Checkout
USD: Business wire transfer (T/T). CNY: WeChat Pay, Alipay, or bank transfer (UnionPay) — the CNY price includes the local currency payment discount.
Delivery
Ex Works (EXW): delivered to the buyer's designated port or a standard warehouse in mainland China. Door-to-door shipping via air, sea, or land: freight charges quoted separately.

Key Features

  • Standard square design, compatible with CYY-LK carbon silicon analyzer.
  • Integrates Tellurium (Te) grains to trigger whitening, ensuring precise cooling curves.
  • Stable cooling curve; supports accurate calculation of C%, Si%, and CE/CEL.
  • Balanced version offering optimal stability, efficiency, and material cost.
  • QC = Quick Check, a product code widely recognized in the global foundry industry.
  • Disposable consumables, hygiene, and convenience

Technical Specifications

Product codeCYY-QC2
Product TypeSquare Carbon-Silicon Sampling Cup (Probe Cup)
Main ApplicationAnalyze C%, Si%, CE/CEL using a Carbon-Silicon Analyzer (C-Si Analyzer)
Compatible devicesCYY-LK Carbon-Silicon Analyzer, C-Si Thermal Analyzer with Square Cup Configuration
MaterialPremium heat-resistant material + integrated Tellurium (Te) particles
ShapeSquare
Sampling temperatureGreater than 1300°C ~ 1400°C
Analysis temperature (in sample cup)1250°C ~ 1350°C
Analysis MechanismCooling curve analysis
Measurement specificationsC% (Carbon), Si% (Silicon), CE/CEL (Carbon Equivalent Level), Liquidus Temperature, ΔT
OriginChange Youyi

App

Gray iron foundry needs fast carbon and silicon analysisDuctile iron foundry controls C-Si composition before pouring.Automotive parts factory ensures stable cast iron compositionMotorcycle parts factory controls molten iron qualityMachinery and mechanical factories using gray cast iron and ductile ironCast Iron Valve and Pump Manufacturing PlantThe foundry uses an induction furnace.Foundry needs fast C% and Si% analysis in molten iron.The factory has multiple batches requiring standardization of the carbon and silicon analysis process.
Request a quote

Detailed description

CYY-QC2 is a square silicon-carbon sampling cup, an essential consumable for carbon-silicon analyzers in the cast iron industry.

During cast iron melting, technicians must quickly determine the carbon (C) and silicon (Si) content of molten iron to decide if adjustments are needed before pouring. Molten iron is poured into CYY-QC2. During cooling and solidification, the carbon-silicon analyzer records the cooling curve and processes it to calculate C%, Si%, and CE/CEL (Carbon Equivalent Level).

CYY-QC2 is a flagship product in Changyouyi's square sample cup analysis line. When customers configure the CYY-LK Carbon Silicon Analyzer with square cups, CYY-QC2 serves as the sample cup. Note that CYY-QC2 is not the default standard configuration; Changyouyi also offers the lightweight, portable CYY-CE round cups, which deliver equivalent analytical performance and superior oxidation and moisture resistance during storage. This cup is also recommended for compatible C-Si analyzers available on the market.

Why is CYY-QC2 the key product for carbon-silicon analyzers? - It is the flagship item in Changyouyi's square sample cup line. - Required when customers select the square cup configuration for the CYY-LK device. - Integrated with Tellurium (Te) particles to promote white iron solidification, ensuring accurate cooling curves for C-Si analysis. - CYY-QC2 is not the default standard configuration—Changyouyi also offers round cups (CYY-CE), which are lighter, easier to transport, and provide better oxidation and moisture resistance during storage, with equivalent analytical performance.

Main application of the carbon-silicon analyzer: CYY-LK Carbon Silicon Analyzer → collect molten iron sample → pour into CYY-QC2 → record cooling curve → analyze C% → analyze Si% → calculate CE/CEL → support composition control before pouring.

QC in CYY-QC2 stands for Quick Check, forming an easily recognizable product code system for international customers in the field of rapid temperature sampling cups — also known as quick analysis cups or carbon silicon probe cups.

CYY-QC2 and other consumables from Changyouyi: In addition to CYY-QC2,, Changyouyi also offers the CYY-CE Series (CYY-CE1/CE2/CE3 (CE Thermal Analysis Round Cup), the CYY-SG Series (CYY-SG1/SG2/SG3 (SG Thermal Analysis Cup for crystallization analysis), and the CYY-QC Series (CYY-QC1/QC2/QC3 (Quick Square Thermal Analysis Cup).

Customers should verify the cup before purchasing: Although many products on the market are labeled as "Silicon Carbon Cup," "Carbon Cup," "Thermal Analysis Cup," or "Quick Cup," their actual designs may vary. When ordering CYY-QC2,, please provide photos of your current cup, packaging label, analyzer machine, and model number. Changyouyi will review these details to minimize the risk of ordering the wrong cup type.

Frequently Asked Questions

Other names / Related keywords

Silicon carbide sampling cupC-Si Analysis Probe CupSquare Pyrolysis Sampling CupCarbon and Silicon Analyzer Sampling CupSquare probe cup for CS analyzerThermal analysis sampling cup, squareCoke sampling carbon silicon analyzercarbon silicon coke sample analyzermeasuring cupThermal analysis sampling cupsquare thermal analysis sample cupSilicon carbon sampling cupC-Si Analysis Sampling CupSquare-shaped heat-resistant cup